INSTALLATIONSGUIDE
18 steg till en färdig Manuell bioklimatisk pergola.
Fristående bioklimatisk aluminiumpergola med manuell vev — ingen motor, ingen firmware, tre omkretsstorlekar från en gemensam 18-stegsprocedur.
-
01
Systemutsättning och referenslinje
Set the system datum and mark the four foot-plate centres on the slab.
STOMME18 min -
02
Placera fotplattor
Place the four PN-FP-500 foot plates and anchor with M10 buldex.
STOMME25 min -
03
Res de fyra pelarna
Lift each PN-DZ-500 pillar onto its foot plate stud — two installers per pillar.
STOMME25 min -
04
Montera bakre bärränna
Install the rear PN-GU-500 carrier gutter — slope 1.5% toward the front.
STOMME18 min -
05
Montera främre bärränna
Install the front PN-GU-500 carrier gutter — match heights within 2 mm.
STOMME18 min -
06
Montera siderännor
Install left and right PN-GU-501 side gutters — verify diagonals (3×3: 386 · 3×4: 466 · 3×5: 554.5 cm).
STOMME25 min -
07
Täta hörnskarvar
Apply neutral-cure silicone bead at all four upper corner joints.
STOMME12 min -
08
Montera lamell-sidoskenor
Slide PN-LR-500 blade side rails into the frame — pre-set pivot positions.
LAMELLER18 min -
09
Förbered lameller
Prepare the louvre blades — fit pivot pins, lay out on a clean covered surface.
LAMELLER18 min -
10
Montera första lamellen
Install the first blade — verify free rotation and flush closed position.
LAMELLER15 min -
11
Slutför lamellfältet
Complete the blade array — equal pitch using a spacer gauge.
LAMELLER25 min -
12
Anslut manuell mekanism
Connect PN-SC-500 manual linkage — all blades must move together.
LAMELLER20 min -
13
Montera manuell vev
Install PN-CR-500 crank gear and PN-GT-500 drive shaft — test full cycle.
LAMELLER20 min -
14
Ställ in öppna/stäng-ändstopp
Set crank end-stops for fully closed and fully open positions.
LAMELLER18 min -
15
Montera avslutningsprofiler
Install PN-CP-500 pillar caps and PN-CP-501 gutter closing profiles.
AVSLUTNING15 min -
16
Montera dräneringsutlopp
Connect PN-WT-100/PN-WT-101 drainage tubes inside front pillars and test water flow.
AVSLUTNING18 min -
17
Slutligt funktionstest
Final functional test — open, close, verify even closure across array.
AVSLUTNING12 min -
18
Rengör och överlämna
Clean powder coating, demonstrate to customer, hand over warranty card.
AVSLUTNING12 min
Om denna manuell bioklimatisk pergola-installationsguide
Luxa Sereno 500M — Manuell bioklimatisk pergola · LuxaShade aluminium roof family. 18 steps · 2 installers · Edition 2026.1.
EN AW-6063 T6 alloy · QUALICOAT class 2 powder coating · EN 1991-1-4 wind-load rated · RTS-compatible motor wiring on motorised variants.
Varför följa det officiella PONARC × LuxaShade-förfarandet
- EN 1991-1-4 · QUALICOAT class 2 · EN AW-6063 T6
- RTS-compatible motor wiring (motorised variants)
- Gutter slope 1.5% · drainage inside columns
- Edition 2026.1 · Januari 2026 · SV